Analytical method: 6.7.12 JDS4.PM.SW.1
Analytical method code |
JDS4.PM.SW.1 |
Name |
LC/MS |
Determinand |
Cybutryne |
Determinand Code |
6.7.12 |
CAS# |
28159-98-0 |
Unit |
µg/l |
Quantification limit |
0.01 |
Uncertainty |
20% |
Validation |
|
Reference to literature |
ČSN EN ISO/IEC 17025:2018 |
Is the laboratory accredited for the given analyte? |
Y |
Sample preparation method |
Solid-phase extraction (SPE) using columns |
Has the used method been validated according to a protocol? |
Within-laboratory validation (full method internal validation at research level) |
Was a field blank checked? |
N |
Is the laboratory accredited according to ISO 17025? |
Y |
Does the laboratory participate in interlaboratory studies for the given determinand? |
Y |
Summary of performance of the laboratory in interlaboratory studies for the given determinand |
z<3 |
Are the data controlled by a competent authority (apart from accreditation bodies)? |
N |